Installation

6

12" (30.5

cm) Ma

ntle

36"

(91cm)

3"

(7.6cm)

24"

(61cm)

Floor P

rotectio

n;

Min 6" (1

5 cm) in

front of

door

Figure 4: Empress FPI Clearance to Combustibles.

C

LEARANCES

TO

C

OMBUSTIBLES

:

42

5

/

8

" (1083mm)

24

1

/

16

"

(611mm)

28

9

/

16

"

(725mm)

31

3

/

8

"

(797mm)

Figure 3: Dimensions of Empress Fireplace Insert with Optional Skirt.

Refer to Figure 4.
Side wall to center of unit 24 inches (61.0 cm)
Side wall to surround

3 inches (7.6 cm)

Mantel projection

12 inches (30.5 cm)

Mantel to bottom of unit 36 inches (91.4 cm)
Top facing to unit

0 inches (0 cm)

Side facing to unit

0 inches (0 cm)

The floor 6 inches (15.2 cm) on either side of

the unit and to the front must be protected by

a non-combustible material.