Technical data – Profoto D2 500Ws AirTTL Monolight User Manual
Page 24
D2
500
/1000 Air
TTL
24
www.profoto.com
Technical data
.
1000
500
Energy
1000 Ws
500 Ws
Energy range
10 f-stops
(2-1000 Ws)
10 f-stops
(1-500 Ws)
Energy control
increments
1/10 or full f-stops
1/10 or full f-stops
Recycling time
0.03 - 1.2 s
0.03 - 0.6 s
Quick burst
Up to 20 flashes/s
Up to 20 flashes/s
Flash duration Normal
mode (t0.5)
1/1,600 s (1000 Ws)
- 1/11,000 s (2 Ws)
1/2600 s (500 Ws)
- 1/17000 s (1 Ws)
Flash duration Freeze
mode (t0.5)
1/1,600 s (1000 Ws)
- 1/50,000 s (2 Ws)
1/2,600 s (500
Ws) - 1/63,000 s
(1 Ws)
Energy stability
Normal mode
+- 1/20 f-stop
+-1/20 f-stop
Energy stability Freeze
mode
+--1/20 f-stop
+-1/20 f-stop
Color stability Normal
mode
+-150 K over range.
+-20 K flash to flash
+-150 K over range.
+-20 K flash to
flash
Color stability Freeze
mode
+-1200 K over range.
+-100 K flash to flash
+-1200 K over
range.
+-100 K flash to
flash
Modeling lamp
Max 300 W
(Halogen)
Max 300 W
(Halogen)
Modeling light modes
Max, Prop, Free, Off
Max, Prop, Free, Off