Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame

setting. To do this, follow the procedure below.

1) Turn the gas tap to the MAX position and ignite.
2) Set the gas tap to the MIN flame position then turn the control knob from MIN to

MAX several times. If the flame is unstable or is extinguished follow the procedure

below.

Procedure:

1) Re-ignite the burner and set to

MIN.

2) Remove the control knob.
3) To adjust, use a thin bladed

screwdriver and turn the

adjustment screw (it can be

located down the centre of the gas

tap shaft or on the tap body,

according to the different models

- see diagram) until the flame is

steady and does not extinguish,

when the knob is turned from MIN

to MAX. Repeat this procedure for

all burners.

Pressure Testing

1) Remove left hand pan support and front left burner cap and crown.
2) Fit manometer tube over the injector.
3) Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20mbar and must be between 17

mbar and 25mbar.

4) Turn off the burner supplies.

)

)

)

)

)

)

)

)

)

)

)

)

)

)

)

Minimum adjustment screw