Time values
Time values
Time values depending on the rectifiers
Although the Attack and Release times can be considered fixed intervals, the con-
trol-time behavior and operating mode of the tubes is very different depending on the
music. That is why these values should not be considered absolute values. The following
chart should give an overview of the dependence of the control times of the input signal
and the chosen Rectifier, with the same preset (OFF) of Side Chain EQ. Attack and Release
were switched in sequence, together, from Fast (A + R position 1) to Slow (A + R position
6). The times were measured with an input signal of frequency 10 kHz.
A + R Position
Attack (msec)
Release (msec)
Rectifier
1
0.1
100
GE 1mF
2
6
150
GE 1mF
3
10
180
GE 1mF
4
18
200
GE 1mF
5
30
220
GE 1mF
6
50
250
GE 1mF
1
1
300
GE 2mF
2
15
450
GE 2mF
3
30
500
GE 2mF
4
40
600
GE 2mF
5
50
700
GE 2mF
6
70
900
GE 2mF
1
3
600
LED 3.3 mF
2
35
1000
LED 3.3 mF
3
70
1700
LED 3.3 mF
4
100
2500
LED 3.3 mF
5
150
3200
LED 3.3 mF
6
220
5000
LED 3.3 mF
1
0.5
80
Si. 330 nF
2
3
120
Si. 330 nF
3
5
160
Si. 330 nF
4
8
180
Si. 330 nF
5
9
220
Si. 330 nF
6
12
300
Si. 330 nF
1
0.3
30
Ge 220 nF
2
1.5
50
Ge 220 nF
3
3
70
Ge 220 nF
4
5
80
Ge 220 nF
5
7
120
Ge 220 nF
6
9
130
Ge 220 nF
1
0.2
20
Ge/Si 100nF
2
0.7
40
Ge/Si 100nF
3
1.5
60
Ge/Si 100nF
4
2.5
80
Ge/Si 100nF
5
4
100
Ge/Si 100nF
6
6
170
Ge/Si 100nF