beautypg.com

Warning, Natural gas conversion – Estate TGP305T User Manual

Page 13

background image

13

Natural Gas Conversion

To Convert Gas Pressure Regulator

1. Turn manual shutoff valve to the “closed” position.
2. Unplug range or disconnect power.

3. Open broiler door and remove broiler pan. The gas pressure

regulator is located in the back right hand corner of the broiler
compartment.

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4. Remove the cap from the gas pressure regulator using a

flat-blade screwdriver.

5. Turn the cap over so that N or NAT is visible.

6. Reinstall the cap.

To Convert Surface Burners

1. Remove burner grate, burner caps and burners.

2. Locate the Natural gas orifice spuds for top burners in the

literature bag included with the range. Three Natural gas
spuds are stamped “149” and one “165.”

3. Remove the LP gas orifice spuds using a 7 mm combination

wrench.

4. Install the Natural gas orifice spuds using a 7 mm combination

wrench.

NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and 1
power burner. Spud size/location remain the same.

A. To range
B. Manual shutoff valve “closed” position

C. Gas supply line

A. Gas pressure regulator

A. Cap

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death
or serious burns to children and adults.

A

B

C

A

A

A. Cap

A. Burner cap
B. Burner

A. Spud
B. Holder

A

A

B

A

B