beautypg.com

页 26, Warning – MIDEA Dryer MLE45N1BWW User Manual

Page 26

background image

WARNING

Electrical Shock Hazard

All U.S. models are produced for a

3-WIRE SYSTEM

CONNECTION

.

The dryer frame is grounded to the neutral conductor
at the terminal block. A

4-WIRE SYSTEM CONNECTION

is required for new or remodeled construction, mobile

homes, or if local codes do not permit grounding through
neutral conductor. If the 4-wire system is used, the dryer

frame cannot be grounded to the neutral conductor at the

terminal block. Refer to the “

Electric Requirements

” section

on page 16 for 3-WIRE or 4-WIRE SYSTEM CONNECTIONS.
Remove the terminal block cover plate.
Insert the power cord with a UL-listed strain relief through

Do not loosen the nuts already installed on the terminal

block. Be sure they are tight. Use a 3/8" (1 cm) deep-well
socket.

the hose provided in the cabinet near the terminal block.

• A strain relief must be used.

Dry

er

Saf

ety

Oper

ation

R

equir

ements

P

arts and

F

eatur

es

Ins
tallation

Ins
tructions

Dry

er Use

Appendix

Dry

er Car

e

T

roubleshooting

26