页 26, Warning – MIDEA Dryer MLE45N1BWW User Manual
Page 26
WARNING
Electrical Shock Hazard
All U.S. models are produced for a
3-WIRE SYSTEM
CONNECTION
.
The dryer frame is grounded to the neutral conductor
at the terminal block. A
4-WIRE SYSTEM CONNECTION
is required for new or remodeled construction, mobile
homes, or if local codes do not permit grounding through
neutral conductor. If the 4-wire system is used, the dryer
frame cannot be grounded to the neutral conductor at the
terminal block. Refer to the “
Electric Requirements
” section
on page 16 for 3-WIRE or 4-WIRE SYSTEM CONNECTIONS.
Remove the terminal block cover plate.
Insert the power cord with a UL-listed strain relief through
Do not loosen the nuts already installed on the terminal
block. Be sure they are tight. Use a 3/8" (1 cm) deep-well
socket.
the hose provided in the cabinet near the terminal block.
• A strain relief must be used.
Dry
er
Saf
ety
Oper
ation
R
equir
ements
P
arts and
F
eatur
es
Ins
tallation
Ins
tructions
Dry
er Use
Appendix
Dry
er Car
e
T
roubleshooting
26