页 12, Ducting requirements – MIDEA Dryer MLE45N1BWW User Manual
Page 12
DUCTING REQUIREMENTS
Recommended
Use only for short-run
installation
Weather Hood
Type
4" DIA
4" DIA
4"
4 inch. (10.2 cm)
4" DIA
2-1/2"
2.5 inch. (6.4 cm)
No. of 90°
elbows
Rigid Metallic
Rigid Metallic
0
90 ft. (27.4 m)
60 ft. (18.3 m)
1
60 ft. (18.3 m)
45 ft. (13.7 m)
2
45 ft. (13.7 m)
35 ft. (10.7 m)
3
35 ft. (10.7 m)
25 ft. ( 7.6 m)
Manometer measurements
The static pressure in any exhaust system for best results shall be between
0.3 to 0.8 inches of water column, and cannot be less than 0 under any
circumstances. with installed duct of 4 inch diameter. Measurement must
be done with the empty dryer working with a manometer at the point
where the exhaust duct connects to the dryer. A no-heat setting should be
used. Lint filter must be clean.
If this new dryer is installed into an existing exhaust system you must make
sure:
•
The exhaust system meets all local, state, and national codes.
•
That a flexible plastic duct is not used.
•
To inspect and clean all lint buildup from inside the existing duct.
•
The duct is not dented or crushed.
•
The exhaust hood damper opens and closes freely.
Dry
er
Saf
ety
Oper
ation
R
equir
ements
P
arts and
F
eatur
es
Ins
tallation
Ins
tructions
Dry
er Use
A
p
p
e
n
d
ix
Dry
er Car
e
T
ro
u
b
le
sh
o
o
tin
g
1
2