beautypg.com

Control device for grease and charcoal filters, Grease filter led (f), Charcoal filter led (c) – Electrolux 8820 User Manual

Page 7: Resetting the saturation indicator

background image

66

Control device for grease and charcoal filters

This hood is fitted with a device that signals when it is necessary to clean the grease

filter or the charcoal filter (if the hood is used in the recirculation version with a

charcoal filter).

On delivery, the hood is not supplied with a charcoal filter, so the saturation indicator

will be disabled.

If the hood is to be used with a charcoal filter, the saturation

indicator light must be enabled as follows:

Press buttons 4 and 5 simultaneously and hold them for 3 seconds. At first only the

grease filter LED F will illuminate, but when the charcoal filter LED C illuminates the

saturation indicator will be enabled.

To disable it: Press buttons 4 and 5 again simultaneously and hold

them for 3 seconds, until the charcoal filter LED C goes out.

Grease filter LED (F)

LED F will start to flash when it is time to clean the grease filter.

Cleaning will be necessary after 40 working hours. Always comply with the

maintenance instructions for the grease filter.

Charcoal filter LED (C)

The charcoal filter LED C will start to flash when the charcoal filter needs to be

replaced.

This operation is necessary after approximately 160 working hours.

Resetting the saturation indicator

After cleaning or replacing the filters, press button 1 for 3 seconds until the grease

filter LED F or the charcoal filter LED C stops flashing.

Warning! The resetting of the saturation indicator MUST be done in stand-by, never

disconnect the hood from the mains.