beautypg.com

Electrolux 726662 User Manual

Page 13

background image

13

C.1.8 TIME

During a chilling cycle: the time display shows the total or
remaining chilling time.
During holding cycle: the display shows the hour.
During “turbo cooling” cycle: the display shows:

°°°°

“ = two hours left until start of defrosting

"

°°°

" = 1.5 hours left until start of defrosting

"

°°

" = 1 hour left until start of defrosting

"

°

" = 0.5 hours left until start of defrosting

The TIMED CYCLE INDICATOR LIGHT

lights up only

when a timed blast chilling cycle is running.
During the cycle selection phase it indicates the chilling time.

The “estimated remaining time” LED

comes on as soon

as the electronic card calculates the time remaining until the
end of cooking with shaft probe. Once it has been measured,
the time is shown on the time display.

C.1.9 UTILITIES

When the

button is pressed it lights up behind. Use the

buttons to scroll backwards and forwards and select

the utility. Press

to confirm.

After entering the “Utilities” menu, the system will go back to the
main menu if no button is pressed for 5 seconds.

See below for a DESCRIPTION OF THE UTILITIES FUNCTIONS.

C.1.9.1 MANUAL DEFROSTING

If the appliance is in the right conditions (indicator light

or

or with the appliance on stand-by), this function

enables a manual defrosting cycle. The display shows the
message “dEfr” throughout the entire cycle.
If a manual defrosting is not possible (during a chilling cycle) the
message “ UTIL NONE” will appear on the display.
The selection is enabled only in preservation/maintenance and
when selecting the operating cycle.
When the defrosting is finished the system will go back to the
main configuration.

C.1.9.2 PROBE TEMPERATURES DISPLAY

This function displays the probe temperatures, if there is more
than one probe inserted in the product.
If just one probe is used, see section C.1.5 for instructions on
how to display the temperature.

C.1.9.3 "UV"STERILIZATION CYCLE

(Function for appliances with germicidal light option)

The UV lamps have a direct germicidal action and are used to
sterilize the surfaces and air in the chamber of the appliance
(see section B.1.4)
To active "UV", no cycles must be running. When the cycle is
running the “TEMPERATURE” display shows the chamber
temperature. When the cycle is finished the system goes back
to the main menu.
If a sterilization cycle is not possible because of the status of the
appliance, the message “UTIL NONE” will appear on the display.