2. Hardware Installation
The following are instructions for setting up PLANET IPX-2100. Refer to the
illustration and follow the simple steps below to quickly install your Internet
Telephony PBX system.
2.1 Safety Instructions
The following are the safety instructions for Internet Telephony PBX system before
installing.
The maximum operating temperature of the IPX-2100 is -10~45°C. Care must
be taken to allow sufficient air circulation.
The connections and equipment that supply power to the IPX-2100 should
be capable of operating safely with the maximum power requirements of the
IPX-2100. In the event of a power overload, the supply circuits and supply
wiring should be become hazardous.
The power adapter must plug into the right supply voltage. Make sure that the
supplied power voltage is correct and stable. If the input power voltage is over
10% lower than the standard, it may cause the IPX-2100 to malfunction.
Generally, when installed after the final configuration, the product must comply
with the applicable safety standards and regulatory requirements of the country
in which it is installed. If necessary, consult for technical support.
2.2 Physical Introduction
SLOT 1
SLOT 2
IPX-2100
Internet Telephony PBX System
Ringing
FXO
FXS
2
1
3
4
2
1
3
4
PWR SYS
USB
ETH
Figure 2-1 Front Panel of the IPX-2100
USB
Console
ETH
Reset
SLOT 2
12V DC
SLOT 1
Figure 2-2 Rear Panel of the IPX-2100