19
Electrical Specifications
(23°C ±5°C, Four-wire Measurement)
Battery Type
Rechargeable Lithium Battery, 11.1Vdc, 3400mAh
Battery Life
400 times of linear scan from 60V to 0V and 0A to 12A
Data Logging
Memory Size
99 records
AC Adaptor
AC 110V or 220V input
DC 15V / 1~3A output
Dimension
257(L) x 155(W) x 57(H) mm (10.12 x 6.1 x 2.24 inch)
Weight
1160g / 40.0oz (Batteries included)
Operation
Environment
0°C to 50°C (32°F to 122°F), 85% RH
Temperature
Coefficient
0.1% of full scale / °C
(<18°C or >28°C)
Storage Environ-
ment
-20°C to 60°C (-4°F to 140°F), 75% RH
Accessories
User Manual x 1, AC adaptor x 1
Optical USB Cable x 1
Rechargeable lithium battery pack x 1
Software CD x 1, Software Manual x 1
Kelvin Clips (12A max) x 1 set
�
- EMC: EN 61326-1: 2006
- LVD: EN 61010-1: 2001
This product complies with requirements of the flowing European Community
Directive: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low
Voltage). However, electrical noise or intense electromagnetic fields in the
vicinity of the equipment may disturb the measurement circuit. Measuring
instruments will also respond to unwanted signals that may be present within
the measurement circuit. Users should exercise care and take appropriate
precautions to avoid misleading results when making measurements in the
presence of electronic interference.