Precautionary measures, Ordering replacement parts, Troubleshooting guide – Euro-Pro BPV325H User Manual
Page 4
PRECAUTIONARY MEASURES
2
1.
Before inserting the power plug
into the wall outlet, make sure that
your hands are dry.
2.
Before you start vacuuming,
make sure to remove large or
sharp objects that might
damage the dust bag.
3.
When pulling out the power plug
from the wall outlet, pull the plug
not the power cord.
4.
Do not pick up anything that is
burning or smoking such as
cigarettes, matches or hot ashes.
5.
Do not use without all filters and
dust bag in place.
6.
Do not vacuum any liquids.
7.
Keep hair, loose clothing, fingers,
feet and all parts of body away
from openings, rotating agitator
and other moving parts.
Important:
If the suction opening of the unit, the hose or the extension tubes are
BLOCKED, switch off the vacuum cleaner and remove the blocking
substance before you start the unit again.
11
ORDERING REPLACEMENT PARTS
TO ORDER REPLACEMENT BAGS
Item #XHB325H
For Model BPV325H
Call: 1 (800) 798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M.
Eastern Standard Time
Please Note:
The HEPA pre-motor and exhaust filters may be washed. We recommend that this be
done once a month or when suction appears reduced .To wash your HEPA pre-motor
filter and exhaust filter, hold and rinse under lukewarm water. When finished, shake off
excess water. DO NOT wash in dishwasher. It is important that when you wash any
filter, you allow it to air dry COMPLETELY before using again. We recommend 24
hours to air dry. DO NOT DRY IN DRYER.
IMPORTANT:
Both the HEPA pre-motor filter and the exhaust filter should be re-placed every three
(3) to six (6) months depending on usage. All filters, the shake-out bag and HEPA
dust bag should be checked regularly for signs of damage, preferable after each
cleaning task. The HEPA dust bag, shake-out bag and filters must be replaced
immediately if they become damaged. Always disconnect the vacuum from the
electrical outlet when checking the filters. NEVER re-use the HEPA dust bags.
Always replace the dust bags with new ones.
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
Motor runs but no
suction
1. Hose extension tube or
air inlet is blocked.
2. HEPA dust bag is full.
3. Hose not assembled to
hose inlet properly.
1. Check for blockage (remove
blockage).
2. Replace HEPA dust bag.
3. Insert hose into hose inlet
and turn counter-clockwise
until it locks into place.
Turbo brush does
not rotate or
rotates slowly
1. Rotating brush or elbow
obstructed.
2. Belt is broken.
3. Hose is obstructed.
4. HEPA pre-motor filter is
blocked.
1. Clear obstructions.
2. Call 1 (800) 798-7398.
3. Clear obstruction.
4. Clean HEPA pre-motor filter.
Vacuum won’t run
1. Not firmly plugged in.
2. No electricity in wall
outlet.
3. Blown fuse/tripped
breaker.
4. Motor thermostat may
have tripped.
1. Plug unit in firmly.
2. Check fuse or breaker.
3. Replace fuse/reset breaker.
4. Turn vacuum off and unplug
from outlet. Allow unit to cool
down before trying to switch
on again.