Amprobe ACD-16-PRO Clamp-Meters User Manual

Page 15

background image

14

Audible Continuity Tester
Audible threshold: between 10

Ω and 300Ω.

Response time: 250

µs


Frequency
Range Accuracy
5.00Hz ~ 500.0Hz

0.5%+4d

Sensitivity (Sine RMS)
40A range: > 4A
400A range: > 40A

1000A range: > 400A
6

00V range: > 30V

Temperature
RANGE Accuracy

1)

-50

o

C ~ 300

o

C 2.0%

+

3

o

C

-58

o

F ~ 572

o

F 2.0%

+

6

o

F

1)

Add 3

o

C (or 6

o

F) to specified accuracy @ -20

o

C ~ -50

o

C (or @ -4

o

F ~ -58

o

F)

T

ype-K thermocouple range & accuracy not included

ACA Current (Clamp-on)
RANGE Accuracy

1) 2) 3)

50Hz / 60Hz
40.00A, 400.0A, 1000A

1.0% + 5d

45Hz ~500Hz
40.00A, 400.0A

2.0% + 5d

1000A

2.5% + 5d

500Hz ~ 3.1kHz (ACD-16TRMS Pro & ACD-40PQ only)
40.00A, 400.0A

2.0% + 5d

1000A

2.5% + 5d

True RMS models Crest Factor:

< 2.5 : 1 at full scale & < 5.0 : 1 at half scale for 40.00A & 400.0A ranges
< 1.4 : 1 at full scale & < 2.8 : 1 at half scale for 1000A range

1)

Add 8d to specified accuracy while reading is below 10% of range

2)

Induced error from adjacent current-carrying conductor: < 0.06A/A

3)

Specified accuracy is for measurements made at the jaw center. When the conductor is not

positioned at the jaw center, position errors introduced are:

Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away

from jaw opening)

Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward

jaws opening)