beautypg.com

Mtl-90b), Tpk-59, Rs-232 kit2 – Amprobe ACD-16-PRO Clamp-Meters User Manual

Page 13

background image

12

Relative Humidity : Maximum relative humidity 80% for temperature up to 31

o

C

decreasing linearly to 50% relative humidity at 40

o

C

Altitude : Operating below 2000m
Storage Temperature : -20

o

C to 60

o

C, < 80% R.H. (with battery removed)

Temperature Coefficient : nominal 0.15 x (specified accuracy)/

o

C @(0

o

C -18

o

C or 28

o

C

-40

o

C), or otherwise specified

Sensing : Average sensing for model 131; True RMS sensing for model 132 & 135
Safety : Meets IEC61010-2-032(1994), EN61010-2-032(1995), UL3111-2-032(1999).

Measurement Category III 600 Volts ac & dc

Transient protection : 6.5kV (1.2/50

µs surge) for all models

Pollution degree : 2

E.M.C. : Meets EN61326(1997, 1998/A1), EN61000-4-2(1995), and EN61000-4-3(1996)

In an RF field of 3V/m:

Total Accuracy = Specified Accuracy + 45 digits

Performance above 3V/m is not specified

Overload Protections :

ACA Clamp-on jaws : AC 1000A rms continuous

+ & COM terminals (all functions) : 600VDC/VAC rms

Power Supply : standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2
Power Consumption :

Voltage & ACA functions: 3.5mA typical
Ohm & Temperature functions: 4mA typical

APO Timing : Idle for 16 minutes
APO Consumption : 10

µA typical

Dimension : L224mm X W78mm X H40mm
Weight : 224 gm approx
Jaw opening & Conductor diameter : 45mm max
Special features : THD%-R Total harmonic distortion-RMS (ACD-40PQ only); Display

Backlight ACD-16 TRMS & ACD-40PQ only); Auto-Hold; Display Hold; On screen
stand-alone Hi-Lo logging (5400 minutes) at sampling speed of faster than:

20 per second for Voltage & ACA functions
4 per second for Ohm & Temperature functions
2 per second for Hz function

Accessories : Test leads

(MTL-90B)

, batteries installed, user's manual,

TPK-59

banana

plug type-K thermocouple & soft carrying pouch
O

ptional accessories :

RS-232 KIT2

interface kit.

Electrical Specifications

Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23

o

C ±5

o

C &

less than 75% R.H.

This manual is related to the following products: