1 / INSTALLING YOUR APPLIANCE

Your appliance should be positioned so that the mains switch is accessible.
These hobs must be connected to the mains using a socket in compliance with publication CEI
60083 or an all-pole circuit-breaker device in compliance with the installation rules in force.
When power is first supplied to your hob, or after an extended power cut, an indicator light will
appear on the control panel. This information will disappear after 30 seconds.

Connection

•Hook-up of 220-240V

~

(DTI11177X -DTI1137X - DTI1047C et GC)

Warning

If the cable is damaged it must be replaced by the manufacturer, its after-sales serv-

ice or a person with a similar qualification to prevent danger.

N

L

Green/yellow

Blue

Brown

32A

Earth

Neutral Phase

Neutral

Phase

N

L

Green/yellow

Blue

Brown

• 220-240 V monophase
hook-up(DTI1177X)

Earth

Bleu

Brown

Green/yellow

Earth

Phase

L

20 A

32 A

Green/yellow

Blue

Brown

Earth

Blue

Brown

Green/yellow

Neutral

N

Phase

L

32 amp fuses.

63 amp fuse.

Neutral

N

Separate the 2 phase wires L1 and L2 before
connection

N

L

Green/yellow

Blue

Black - grey

Brown

Neutral

Earth

Phase

N

L1 L2

Blue

Green/yellow

Black - grey

Brown

220-240V

~

With hook-up of 400 V 2N three phase, verify
that the neutral wie is properly connected

• 400V 2N

~

- 16A

32A

Separate the wires before connection

Neutral

Earth

Phase

N1

L1 L2

Blue

Green/yellow

Black - grey

Brown

2x230V 2L+2N

~

- 16A

N2

Earth

Neutral

Phase

Connection DTI1043XE - DTI1167XE