beautypg.com

Electrolux 16850A User Manual

Page 26

background image

3. Open the pump door.

4. Pull flap forward to remove.

5. Place a container close to the pump to

collect any spillage.

6. Pull out the emergency emptying hose,

place it in the container and remove its

cap.

7. When no more water comes out, un-

screw the pump cover by turning it an-

ti-clockwise and remove the filter. Use

pliers, if necessary. Always keep a rag

nearby to dry up any water spillages

when removing the cover.
Clean the filter under a tap, to remove

any traces of fluff.

8. Remove foreign bodies and fluff from

the filter seat and from the pump im-

peller.

9. Check carefully whether the pump im-

peller rotates (it rotates jerkily). If it

doesn’t rotate, please contact your

Service Centre.

10. Put the cap back on the emergency

emptying hose and place the latter

back in its seat.

26

Care and cleaning