Purdy PO019-12D-2B-2 User Manual
Dc fans and blowers, Features, Dimensions – inches mm air flow vs air pressure
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
7/19/07
Tel: 408.523.8200 • Fax: 408.733.1287 •
•
www.purdyelectronics.com
1
DC Fans and Blowers
PO019-12D-2B-2
PO019-24D-2B-2
Features
Size:
60 x 60 x 25 mm (2.36" x 2.36" x 0.98")
Airflow:
13-19 CFM
Lead Wire:
AWG24 (UL1007, CSA TR-64)
Impeller/Frame: Reinforced Plastic (UL94V-0)
Bearings:
Sealed Ball
Dimensions – inches mm
Air Flow vs Air Pressure
0
Air Volume (cfm)
Static Pressure (inches H
2
O)
.15
.10
.05
.25
.20
0
0
5
10
15
20
Performance
*Measured 1 m from intake
Type
Rated
Voltage
Rated Current
(A)
Max Air
Flow)
Max Air
Pressure
Noise*
Operating
Voltage
Operating
Temperature
Life Expectancy
(Hr)
(V)
Locked
Moved
(CFM
(In H
2
O)
(dBA)
(V)
(°C)
(@ 20°C ±20°)
PO019-12D-2B-2
12
.530
.140
19.4
0.24
34
10.2~13.8
-20 ~ +70
60,000
PO019-24D-2B-2
24
.280
.080
19.4
0.24
34
20.4~27.6
-20 ~ +70
60,000
CSA LR74525
UL E101153
Product specifications contained herein may be changed without prior notice.
It is therefore advisable to contact Purdy Electronics before proceeding with the design of equipment incorporating this product.
• RoHS Compliant