DC Fans and Blowers
PO012-12D-2B-2
PO012-24D-2B-2
Features
Size:
60 x 60 x 25 mm (2.36" x 2.36" x 0.98")
Airflow:
12 CFM
Lead Wire:
AWG24 (UL1007, CSA TR-64)
Impeller/Frame: Reinforced Plastic (UL94V-0)
Bearings:
Sealed Ball
Dimensions – inches mm
Air Flow vs Air Pressure
0
Air Volume (cfm)
Static Pressure (inches H
2
O)
.15
.10
.05
.25
.20
0
0
5
10
15
20
Performance
*Measured 1 m from intake
Type
Rated
Voltage
Rated Current
(A)
Max Air
Flow)
Max Air
Pressure
Noise*
Operating
Voltage
Operating
Temperature
Life Expectancy
(Hr)
(V)
Locked
Moved
(CFM
(In H
2
O)
(dBA)
(V)
(°C)
(@ 20°C ±20°)
PO012-12D-2B-2
12
.220
.080
12
0.094
23
10.2~13.8
-20 ~ +70
60,000
PO012-24D-2B-2
24
.110
.040
12
0.094
23
20.4~27.6
-20 ~ +70
60,000
CSA LR74525
UL E101153
Product specifications contained herein may be changed without prior notice.
It is therefore advisable to contact Purdy Electronics before proceeding with the design of equipment incorporating this product.
• RoHS Compliant