Displays, And-tft-5vx, Interface timing – Purdy AND-TFT-5VX User Manual
Page 6
AND-TFT-5VX
Displays
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
04/22/08
Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected] • www.purdyelectronics.com
6
Interface Timing
Timing Parameters
AC Electrical Characteristics (V
CC
=V
DD1
=3.3V, V
DD2
=9.5V, GND=V
SS1
=V
SS2
=0V, Ta=25ºC)
Parameter
Symbol
Min.
Typ.
Max.
Unit
CLK Frequency
Fclk
–
25
40
MHz
CLK Pulse Width
Tcw
25
40
–
ns
Data Sett-up Time
Tsu
4
–
–
ns
Data Hold Time
Thd
2
–
–
ns
Propagation Delay of DIO2/1
Tphl
6
10
15
ns
Time That the Last Data to LD
Tld
1
–
–
Tcw
Pulse width of LD
Twld
2
–
–
Tcw
Time That LD tp DIO1/2
Tlds
5
–
–
Tcw
POL Set-up Time
Tpsu
6
–
–
ns
POL Hold Time
Tphd
6
–
–
ns
OE Pulse Width
T
OEV
1
–
–
µ
s
CKV Pulse Width
T
CKV
500
–
–
ns
STV Set-up Time
T
SUV
400
–
–
ns
STV Hold Time
T
HDV
400
–
–
ns
Horizontal Display Period
T
HDP
–
640
–
Tcw
Horizontal Period Timing Range
T
HP
–
800
–
Tcw
Horizontal Lines Per Field
T
V
520
525
640
T
HP
Vertical Display Timing Range
T
DV
–
480
–
T
HP
Pixel arrangement
LCD module pixel arrangement is the stripe.
Reliability Test
No
Test Item
Test Condition
Remark
1
High Temperature Storage Test
Ta = +80ºC, 240 hrs
2
Low Temperature Storage Test
Ta = -30ºC, hrs
3
High Temperature Operation Test
Ta = +70ºC, 240 hrs
4
Low Temperature Operation Test
Ta = -20ºC, 240 hrs
5
High Temperature & High Humidity
Operation Test
Ta = +60ºC, 90%RH, 240 hrs
(No Condensation)
6
Thermal Cycling Test
(non-operating)
-30ºC to +80ºC, 100 Cycles
30 min 30 min
7
Vibration Test
(non-operating)
Frequency : 10~55 H
Z
Amplitude : 1 mm
Sweep Time : 11 min
Test Period: 6 Cycles for
each direction of X,Y,Z
8
Shock Test (non-operating)
100G, 6ms
Direction : ±X, ±Y, ±Z
Cycle : 3 times
9
Electrostatic Discharge Test
(non-operating)
200pF, 0
σ ±200V
1 time / each terminal