beautypg.com

Purdy AND1742MST2 User Manual

Page 2

background image

Intelligent Graphics Display

AND1742MST2

Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085

3/21/07

Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected] • www.purdyelectronics.com

2

CCFL Driving
Current

I

FLD

V

FLD

=

450Vrms

f

FL

=

30kHz

5.0

mA

CCFL Driving
Frequency

f

FL

V

FLD

=

450Vrms

f

FL

=

30kHz

15

30

85

kHz

CCFL
Saturation
Time

t

SAT

Ta =

25ºC

1

minut

Electrical Characteristics (TA = 25°C) (Continued)

Item

Symbol

Cond.

Min.

Typ.

Max.

Unit

Optical Characteristics (TA = 25˚C,

φ

= 0°,

θ

= 0)

Item

Symbol

Min.

Typ.

Max.

Unit

Viewing Angle
Range
(when Cr

2)

φ

f(12 o’clock)

34

degree

φ

b(6 o’clock)

41

φ

l(9 o’clock)

35

φ

r(3 o’clock)

30

Rise Time *

Tr

140

mS

Fall Time *

Tf

240

Frame
Frequency *

Frm

64

Hz

Contrast *

Cr

5.2

* Condition: V

DD

- V

EE

= 17.8V, Ta = 25ºC

Connector Pin Assignment

Pin No.

Signal

Function

1

RESET

Controller Reset

2

RD

Data Read

3

WR

Data Write

4

SEL2

MPU Select

5

SEL1

MPU Select

6

CS

Chip Select

7

AO

Command Mode Set

8

D0

Data Input/Output (LSB)

9

D1

Data Input/Output

10

D2

Data Input/Output

11

D3

Data Input/Output

12

D4

Data Input/Output

13

D5

Data Input/Output

14

D6

Data Input/Output

15

D7

Data Input/Output (MSB)

16

V

DD

Power Supply (5V)

17

GND

Ground

18

V

O

Contrast Adjustment Voltage

19

V

EE

Power Supply for LCD Drive

20

FGND

Frame Ground

Environmental Absolute Maximum Ratings

Item

Normal Temperature

Wide Temperature

Operating

Storage

Operating

Storage

Min.

Max.

Min.

Max.

Min.

Max.

Min.

Max.

Ambient Temperature

0ºC

+50ºC

-20ºC

+70ºC

-20ºC

+70ºC

-30ºC

+80ºC

Humidity (without condensation)

Note 2,4

Note 3, 5

Note 4,5

Note 4,6

Note 2: Ta

50ºC: 80% RH max. Ta > 50ºC: Absolute humidity must be lower than the humidity of 85% RH at 50ºC.

Note 3: Ta at -20ºC will be < 48 hrs at 70ºC will be < 120 hrs when humidity is higher than 75%.
Note 4: Background color changes slightly depending on ambient temperature. This phenomenon is reversible.
Note 5: Ta

70ºC: 75% RH max. Ta > 70ºC: absolute humidity must be lower than the humidity of 75% RH at 70ºC.

Note 6: Ta at -30ºC will be < 48 hrs, at 80ºC will be <120 hrs when humidity is higher than 75%.