beautypg.com

Warning, Way wirlng diagram: new construction, Way installation – Emerson KF240PRZ00 User Manual

Page 14

background image

3. Before installing wall control, place wall

control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.

4. Install a wall control in the wall box

containing the “hot” wire first. Connect
the black wire of the wall control to the
“hot” wire. Securely connect wires with
wire connectors supplied.

5. Connect one black wire of the wall

control to both remaining traveler wires
in the wall box and secure with wire
connector supplied.

NOTE: Retrofit 3-way installations are
likely to include two traveler wires
between the two wall boxes. In new
construction, only one traveler wire Is
required.

3-WAY WIRlNG DIAGRAM:
NEW CONSTRUCTION

6. Place wall control into wall box. Screw

in place and install decorator style
faceplate (included).

7. Next, install the other wall control into

the wall box containing the load wire.
Connect the black wire of the wall
control to the traveler wire(s) already
connected to the black wire (in the
other wall box). Secure with wire
connectors supplied.

8. Connect one black wire of the wall

control to the “load” (black) wire and
secure with wire connector supplied.

4. Connect one black wire of wall control

to the “hot” wire. Securely connect
wires with wire connectors supplied
(Figure 20).

5. Connect one black wire of wall switch

to the “load” (black) wire in wall box.
Securely connect wires with wire
connector supplied.

6. Screw wall control into wall box and

install decorator style faceplate
(included). Leave wall control in “OFF”
mode until fan installation is completed.

7. Refer to page 5 and complete the

ceiling fan installation.

Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.

!

WARNING

Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.

!

WARNING

EMERSON

®

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

BLACK

BLK

HOT

FAN/LIGHT
WALL
CONTROL

WALL
BOX

TO LOAD

TO

120VAC

SOURCE

G

RO

UN

D

Figure 20

3-WAY INSTALLATION

(On fan controlled by two different wall
controls) (See Figures 21 and 22.)

1. Disconnect power at circuit breaker or

remove fuse.

2. At all wall box locations remove

faceplates and screws from existing
controls. Pull controls out from wall
boxes and determine which wall box
contains the “hot” lead and which wall
box contains the “load” wire. Also,
identify traveler wires which are
common to both wall boxes.
Disconnect wires from existing controls
only. Do not attempt to disconnect any
wires not already connected to existing
controls.

HOT

BLACK

FAN/LIGHT

WALL

CONTROL

TRAVELER

WIRE

BLK

BLK LOAD

BLACK

GROUND

NEUTRAL

REMOTE CONTROL
RECEIVER LOCATED
WITHIN THE CEILING
COVER

EMERSON

®

EMERSON

®

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

HI

MED

LOW

FAN OFF

LIGHT

ON

OFF

14

Figure 21

BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 14