beautypg.com

4. dip switch setting, 4-1. serial interface specification, Page - 9 – Epson WorkForce RP-310 User Manual

Page 10

background image


Page - 9-


2-4. DIP SWITCH SETTING

The RP-300 is set up at the factory to be appropriate for almost all users. It does,
however, offer some settings for users with special requirements .
It has DIP switches that allow you to change communication setting, such as handshaking
and parity check, as well as print density.
Your printer has two sets of DIP switches. The functions of the switches are shown in the
following tables.

? Note : Power off. And open the cover of Dip Switch and change setting.

2-4-1. Serial Interface Specification

DIP Switch Set 1 Functions

SW

FUNCTIONS

ON

OFF

DEFAULT

1

Data Receive Error

Ignore

Print “ ?”

OFF

2

Hexadecimal

HEXDUMP

NORMAL

OFF

3

Hand Shaking

XON/OFF

DTR/DSR

OFF

4

Data Length

7bits

8bits

OFF

5

Parity Check

ENABLED

DISABLED

OFF

6

Parity Check

EVEN

ODD

OFF


Baud rate selection

Transmission speed

SW-7

SW-8

4800 baud

ON

ON

9600 baud

OFF

ON

19200 baud

ON

OFF

38400 baud

OFF

OFF


DIP Switch Set 2 Functions

Print Density

Print Density

SW-1

SW-2

Lower Power

ON

ON

Normal

OFF

ON

Normal

ON

OFF

Dark

OFF

OFF


Cutter

SW

FUNCTIONS

ON

OFF

Remarks

3

Cutter

FULL CUT

PARTIAL CUT

Only Epson mode


Emulation

FUNCTIONS

SW-4

SW-5

Epson (TM-88)

OFF

OFF