4. dip switch setting, 4-1. serial interface specification, Page - 9 – Epson WorkForce RP-310 User Manual
Page 10

Page - 9-
2-4. DIP SWITCH SETTING
The RP-300 is set up at the factory to be appropriate for almost all users. It does,
however, offer some settings for users with special requirements .
It has DIP switches that allow you to change communication setting, such as handshaking
and parity check, as well as print density.
Your printer has two sets of DIP switches. The functions of the switches are shown in the
following tables.
? Note : Power off. And open the cover of Dip Switch and change setting.
2-4-1. Serial Interface Specification
DIP Switch Set 1 Functions
SW
FUNCTIONS
ON
OFF
DEFAULT
1
Data Receive Error
Ignore
Print “ ?”
OFF
2
Hexadecimal
HEXDUMP
NORMAL
OFF
3
Hand Shaking
XON/OFF
DTR/DSR
OFF
4
Data Length
7bits
8bits
OFF
5
Parity Check
ENABLED
DISABLED
OFF
6
Parity Check
EVEN
ODD
OFF
Baud rate selection
Transmission speed
SW-7
SW-8
4800 baud
ON
ON
9600 baud
OFF
ON
19200 baud
ON
OFF
38400 baud
OFF
OFF
DIP Switch Set 2 Functions
Print Density
Print Density
SW-1
SW-2
Lower Power
ON
ON
Normal
OFF
ON
Normal
ON
OFF
Dark
OFF
OFF
Cutter
SW
FUNCTIONS
ON
OFF
Remarks
3
Cutter
FULL CUT
PARTIAL CUT
Only Epson mode
Emulation
FUNCTIONS
SW-4
SW-5
Epson (TM-88)
OFF
OFF