Fluidyne Control Systems 6650 Series Fuel Consumption Monitor User Manual
Series 6650 : fuel consumption monitor, Specifications, Installation

Fluidyne Control Systems (P) Ltd.
S. No. 79/2,Plot No.12, Near Agarwal Godown, Shivne,
Pune-411 023. India
Tel.: 020-25290504, 25290870 Fax: 020-25292773
E-mail: [email protected]
Series 6650 : Fuel Consumption Monitor
For High Pressure Fuel Injected Engine
Capacity : 50-1500 HP
www.fluidyne.co.in
Specifications
Measurement Flow Range 12-500 LPH
Accuracy ±0.5% of reading
Service Diesel
Operating Temp. 0-70 C
Display 8 2 Dot matrix LCD back light display.
Fuel Totaliser - 999999.9 lit.
Engine Run Time - 999999.99 Hrs/mins.
Filter Element 25 micron paper replacable type.
Power Supply 12V DC from cranking battery
Port Size Inlet - 3/4” BSPF
Outlet - 1/2” BSPF
Return - 1/2” BSPF
Material MS fabricated frame for ground mounting
of unit.
Serial Output RS 485 MODBUS RTU optional
0
Fuel Inlet
Line
Storage Tank
Injector
Fuel Pump Return
Oil Filter
Return
Suction Filter
Suction Hose
Engine
Water
Separator
Installation
Liquid Inlet
3/4"BSPF
LIquid Outlet
To Engine
1/2"BSPF
1/2"BSPF
LIquid Return
From Engine
200.0
200.0
4
5
0
.0
3
0
0
1
3
7
.8
2
Dimensions
:
:
:
:
:
:
:
:
:
:
:
:
x
24V DC
Battery
Features
Introduction
The fuel consumption monitor is a compact fuel flow
measuring system for high pressure fuel injected engine
of all makes. The unit handles the return flow and
calculates and displays net engine consumption. It is most
suited for use with Gensets, diesel driven machinery.
·
·
·
·
·
·
Accuracy guaranteed over 12-500 LPH consumption.
Measures net consumption with single flow sensor.
Gravity head not essential for operation.
Built in high capacity filter.
Works on 12V DC supply from cranking battery.
Provided with sturdy mounting frame.
RS 485 Serial output interface, optional for PLC / SCADA.
·