beautypg.com

Thermo Pride DryR22 (LX-13) User Manual

Page 11

background image

11

FIGURE 11: Thermostat Chart - Single Stage AC with PSC Furnace

AC 5B

Single Stage Air Conditioner – Single Stage PSC Furnace

C

24 – Volt Common

Y

Compressor Contactor

SINGLE STAGE

AIR

CONDITIONER

SINGLE STAGE

AIR CONDITIONER

Y

Full Stage Compressor

G

Fan

*BP11C50124

*BN11C01124
*DP11C40124

*DN11C00124

THERMOSTAT

RH

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

W

Full Stage Heat

Selection of GAS/ELEC

switch on thermostat

is not necessary

C

24 – Volt Common

Y

Full Stage Compressor

G

Fan

*BN11C00124

THERMOSTAT

RH

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

W

Full Stage Heat

Thermostat Installer Setup

1-System Type-must be

set to 0

C

24 – Volt Common

Thermostat Installer Setup
15-Compressor Protection

must be set to 5

External Humidistat

(Optional)

Open on Humidity Rise

G*9F

G*(8/9)S

F*(8/9)S

PS(8/9)

ID MODELS

GF(8/9)

G8C

L*8S

C

24 – Volt Common

R

24 – Volt Hot

W

Full Stage Heat

Y / Y2

Second or Full

Stage Compressor

SINGLE STAGE PSC

FURNACE

G

Fan

SINGLE STAGE

PSC

FURNACE

Y1

Single Stage Compressor

Other Part Numbers:

SAP = Legacy

265902 = 031-09167

1

1

24VAC Humidifier

(Optional)

2

Part Number:

S1-2HU16700124

2