beautypg.com

Ventilation requirements, Levelling, Door reversal – Electrolux 160 RA User Manual

Page 15

background image

15

VENTILATION REQUIREMENTS

The appliance must have adequate ventilation to

ensure correct operation.
The diagram shows the ventilation requirements when

installed:
A* Under a worktop or cupboard

B freestanding
* The clearance space of 10cm above the appliance

may be reduced to 5cm providing a clearance space

of 2.5cm is left either side of the appliance.

LEVELLING

The appliance MUST be level. Level the appliance by

adjusting the two adjustable feet (1) at the front of the

appliance.
If required the washer (2) can be removed.

DOOR REVERSAL

Should you wish to reverse the direction that the door

opens, follow the instructions and diagrams below.
Ensure that the appliance is disconnected from

the electricity supply before reversing the door.
To reverse the bottom hinge assembly proceed as

follows:

Tilt the appliance backwards, resting the top edge

of the appliance on a stool or something similar.
Unscrew the adjustable feet situated on both sides

at the front (2 pieces). Remove the lower door

hinge plate by unscrewing the 3 retaining screws.
Remove the hinge pin from the bottom of the door.
Slot the hinge pin into the hole in the hinge pin plate

and relocate the hinge pin assembly to the opposite

location and refit using the retaining screws.
Return the cabinet to an upright position.