Rose Electronics Vista Remote 2 User Manual
Page 47
![background image](https://www.manualsdir.com/files/859247/content/doc047.png)
Vista Remote 2 Installation and Operations Manual
41
change the Scan Time to another interval press and release the left
enter the new scan time interval (1-16 seconds), and press
Reset
To “Reset” the mouse and keyboard, press and release the left
command is used to reset the mouse and keyboard on the currently selected Vista Remote 2
port without removing power from the Vista Remote 2 switch. This is most useful to reset a
PS/2 mouse that has been unplugged and plugged back in. Upon issuing this command, all
keyboard LEDs will go on and then return to their previous state.
Reset computer mouse type (NT and WIN 2K systems only)
DO NOT issue this command on non-NT or Win 2K based computers.
Press and release the left
command to the currently selected NT or Win 2K computer. The command is used to recover a
stuck mouse on an NT or Win 2K system.
Send null byte
Press and release the left
an out-of-sync PS/2 mouse. The command may need to be entered once or twice, depending if
the mouse is out-of-sync by one or two bytes.
Identify ROM version
Press and release the left
revision level of the Vista Remote 2 firmware currently installed. Before entering this command,
the selected CPU must be at a command prompt, word processor, or text editor, so when the
Vista Remote 2 switch sends the ROM revision level the result can be displayed.
Keep command
Press and release the left
Mode command
The Vista Remote 2 switch supports keyboard modes 1, 2 and 3 and mouse modes 7,8, and 9.
To issue the “Mode” command, press and release the left
mode number (1,2,3,7,8,9) followed by
Mode 1 - CPU Keyboard = PC Mode 1 (Some IBM’s & PS/1’s)
Mode 2 - CPU Keyboard = PC Mode 2 (Most PCs)
Mode 3 - CPU Keyboard = Most (RISC) Unix Workstations & Rose Translator
Mode 7 - CPU Mouse = 2 Button Serial (Microsoft) (7 Bt)
Mode 8 - CPU Mouse = 2 Button Serial (Not Used) (8 Bt)
Mode 9 - CPU Mouse = 3 Button Serial (Mouse Systems)
Maximum computers
Press and release the left
unit, if no computers were connected to ports 7 and 8, setting maximum computers to 6 would
bypass scanning computers 7 and 8.
Typematic command
Initial factory setting = 43. Rate = 10.9 chars/sec, Delay = 500 millisec. See Attachment H for
typematic value calculations.
Mouse type
To issue the “Mouse type” command press and release the left
mouse type (0,1,2), and press
Mouse type 0 = PS/2 mouse
Mouse type 1 = Serial mouse
Mouse type 2 = Wheel mouse