Fan performance, Retrotec fan flow for each range, Open – Retrotec Air Leakage Test Systems Selector User Manual
Page 5

Model 200 fan
(reduce by 15% for 50Hz)
Low Flow
Free Air (no flex duct)
25 Pa
680
7 to 620
321
3.3 to 293
1155
12 to 1054
Model 2350 fan
(reduce by 15% for 50Hz)
Standard
Free Air
50 Pa
6,300
5 to 5,600
2,973
2 to 2,643
10,704
8 to 9,514
Model 3300SR fan
High Output
Free Air
50 Pa
300 Pa
8,500
5 to 8,300
2,300
4,012
2 to 3,917
1,085
14,440
8 to 14,100
3,907
Page 5 of 8
Open
Mid
Low
A
B
C
Open
Fan Performance
Maximum Fan Flow Rates
Flow into:
CFM
L/s
m
3
/h
Low Flow fan Range Plates.
Standard Range Plates.
Range Rings allow one fan to test a wide range of
enclosures, from super leaky to super tight. Standard and
High Output fans include 11 flow ranges (far right) to
provide accurate results over the widest range of
enclosure volumes.
Test the tightest (7 CFM) or leakiest (620 CFM) residential
ducts with the three Range Configurations included with
the Low Flow Model 200 fan (right).
Set the Range Configuration on Retrotec’s DM-2 digital
gauge to match the installed Range Ring and get
instant and accurate results in any desired units.
The wide span between the minimum/maximum flow on each Range Configuration, coupled with a huge number of
ranges, enables faster tests over the widest range of buildings or enclosures.
1 CFM
1 m
3
/hr
1 L/s
10
17
5
5
7
100
170
47
1,000
1,700
472
10,000
17,000
4,719
Retrotec Fan Flow for each Range
(Flow at 50 Pascals)
Open
Open
Mid
Low
A
B
C8
C6
C4
C2
C1
L4
L2
L1
Low Flow 200 fans (50Hz)
Low Flow 200 fans (60Hz)
Standard fans (110v/50Hz)
Standard fans (120v/60Hz)
High Output fans (all voltages)