LuMIN8 Installation Instructions

5

Dipswitch Settings

Note:

All switches must be positioned before powering up.

SW

Description

SW1:
SCB/SAB

Used to select SAB or SCB mode for the sounder.
ON (SCB): Current for the sounder will be drawn from the sounder’s rechargeable
battery.
OFF (SAB): Current for the sounder will be drawn from the control panel.

SW2-SW4:
A1, A2, A3

The operation of the dipswitches varies according to the sounder operation mode (BUS or
Stand Alone) as defined by SW5.
Stand Alone Mode (SW5 OFF):

SW2 (A1) Used to control the Sounder Current.

ON: Low current mode. The sound output will be reduced to 105dB 150mA

(1 piezo).

OFF: Normal current mode. The sound output will be 111dB 350mA (1 piezo).

SW3 (A2): Used to select the Sounder Sound.

ON:

=Low Sweep tone

OFF: High Sweep tone

SW4 (A3): Used to define Engineer Maintenance Mode (2 options available).

ON: The Engineer may disable the box tamper (built-in bell tamper ring) by removing

the 12V+ for 3 seconds. This mode will be indicated by a single flashing LED. To
return the sounder to the normal mode, remove the power for 10 seconds.

OFF: Application of 12V to the SET+ input will place the sounder in Engineer

Maintenance Mode. When in Engineer Mode, the sounder tamper signal is
active.

BUS (Serial) Mode (SW5 ON):

SW2-SW4:

=Used to set a unique ID number for the sounder when connected in serial

mode (ProSYS or GT serial control panels).

============================================

=

SW5:
BUS/STD

Defines the operation mode of the sounder.
ON (BUS): BUS (Serial) mode. Use when connecting to ProSYS Freecom or GT

control panels.

OFF (STD): Stand Alone mode.