Top discharge multi-zone system matches – EMI T3HB User Manual
Page 4

Phone: 1-800-228-9364
Fax: 1-800-232-9364
5780 Success Drive,
Rome, NY 13440
CAHB
T2HB, T3HB, or T4HB
Top Discharge
top DIsCHargE muLtI-ZonE systEm matCHEs
notE:
Due to EMI’s ongoing development programs, design and specifications may change without notice.
cahb / t2h, t3h, or t4h SyStem
performance data
Model
Cooling
Heating
Outdoor
Indoor Air
Handler
Btuh
SEER SHR EER
Btuh
COP
T2HB8800
(2) CAHB24
36000
13
0.75 12.3 24400
3.1
T2HB8400
(2) CAHB24
42000
13
0.71 12.1 30600
3.1
T2HB4400
(2) CAHB24
48000
13
0.67 11.7 36800
3.1
T2HB2400
(1) CAHB12 +
(1) CAHB24
35000
13
0.69 11.5 27600
3.1
T2HB9800
(1) CAHB12 +
(1) CAHB24
27200
13
0.76 11.9 19400
3.1
T3HB9990
(3) CAHB12
27800
13
0.80 11.6 21800
3.2
T3HB9920
(3) CAHB12
29800
13
0.78 11.4 23800
3.1
T3HB9980
(2) CAHB12 +
(1) CAHB24
36400
13
0.77 11.9 26800
3.1
T3HB9940
(2) CAHB12 +
(1) CAHB24
42500
13
0.72 11.6 33000
3.1
T3HB9220
(3) CAHB12
31800
13
0.76 11.3 25600
3.1
T3HB9280
(2) CAHB12 +
(1) CAHB24
38500
13
0.75 11.8 28600
3.1
T3HB9240
(2) CAHB12 +
(1) CAHB24
44500
13
0.71 11.8 34800
3.1
T3HB2280
(2) CAHB12 +
(1) CAHB24
40500
13
0.75 11.7 30400
3.1
T3HB2240
(2) CAHB12 +
(1) CAHB24
46500
13
0.71 11.5 36800
3.1
T3HB2220
(3) CAHB12
34000
13
0.75 11.3 27600
3.1
T4HB9999
(4) CAHB12
37200
13
0.8
11.6 29200
3.2
T4HB9992
(4) CAHB12
39000
13
0.78 11.5 31000
3.1
T4HB9922
(4) CAHB12
41000
13
0.77 11.4 33000
3.1
T4HB9222
(4) CAHB12
43000
13
0.75 11.2 34800
3.1
T4HB2222
(4) CAHB12
45000
13
0.75 11.3 36800
3.1
Circuit Designators: 9 = 9000 Btuh 2 = 12000 Btuh 8 = 18000 Btuh 4 = 24000 Btuh