Explosion protection – parameters
1. Non-secure power circuits
1.1 Telephone network
(Clamps A/B no.: 13 – 14)
Maximum input voltage U
m
(call voltage)
AC 90 V
Permissible frequency range
16...54 Hz
or
Maximum input voltage U
m
(supply voltage)
DC 66 V
Maximum input rated current
100 mA
Maximum input short circuit current I
K
35 A
(In the input of this device is a fuse
with a disconnect threshold of 35 A.)
1.2 External second alarm: only for the connection to passive
conductors
(Clamps Bell shunt1, Bell shunt no.: 15 –16)
Maximum call voltage
AC 90 V
Frequency range
16...54 Hz
or
Maximum supply voltage
DC 66 V
2. Secured Circuits
2.1
Headset (microphone)
(Clamp pair HSM no.: 5 – 6)
Maximum
output voltage
U
o
17
V
Maximum
output current
I
o
90
mA
Maximum
output rating
P
o
80
mW
Maximum
external capacity
C
o
375
nF
Maximum
external inductance
L
o
1,2
mH
2.2
Headset (earphone) or second receiver
(Clamp pair HSR No.: 7 – 8)
Maximum
output voltage
U
o
17
V
Maximum
output current
I
o
110
mA
Maximum
output rating
P
o
190
mW
Maximum
external capacity
C
o
375
nF
Maximum
external inductance
L
o
1,2