beautypg.com

MEDC Ex ResistTel MB User Manual

Page 14

background image

14

Explosion protection – parameters

1. Non-secure power circuits

1.1 Telephone network
(Clamps A/B no.: 13 – 14)
Maximum input voltage U

m

(call voltage)

AC 90 V

Permissible frequency range

16...54 Hz

or
Maximum input voltage U

m

(supply voltage)

DC 66 V

Maximum input rated current

100 mA

Maximum input short circuit current I

K

35 A

(In the input of this device is a fuse
with a disconnect threshold of 35 A.)

1.2 External second alarm: only for the connection to passive
conductors
(Clamps Bell shunt1, Bell shunt no.: 15 –16)
Maximum call voltage

AC 90 V

Frequency range

16...54 Hz

or
Maximum supply voltage

DC 66 V



2. Secured Circuits

2.1

Headset (microphone)

(Clamp pair HSM no.: 5 – 6)

Maximum

output voltage

U

o

17

V

Maximum

output current

I

o

90

mA

Maximum

output rating

P

o

80

mW

Maximum

external capacity

C

o

375

nF

Maximum

external inductance

L

o

1,2

mH


2.2

Headset (earphone) or second receiver

(Clamp pair HSR No.: 7 – 8)

Maximum

output voltage

U

o

17

V

Maximum

output current

I

o

110

mA

Maximum

output rating

P

o

190

mW

Maximum

external capacity

C

o

375

nF

Maximum

external inductance

L

o

1,2

mH





This manual is related to the following products: