beautypg.com

MEDC Ex ResistTel MB User Manual

Page 13

background image

13


In order to hang up the secure accessories of the second receiver or
headset, a metal clamp is designated, which is only delivered together
with the headset. In order to mount the metal clamp to the telephone,
two screw sockets are placed in the ground of the casing. The metal
clamp has corresponding bores, which allows for a mounting on the
bottom of the casing through counter sunk bolts (see device overview
on page 7). Thus, the raiser must first mount this on the bottom of the
casing when using the metal clamp. After this, the wall assembly occurs.

Secure program interface

From the cast, an 8-pin, secure connecting plug comes out (14) (see
device overview on page 8). It is only used by the manufacturer for
programming purposes. The connecting plug is to be left blank.
Programming through the raiser is not permissible.

Secure strand connection to the installed speaker

From the casting, a secure 2-pin strand line (16) (see device overview
on page 8), guided to the installed speaker. It is soldered under casting
and on the speaker.

Secure strand connection to the reed contact

From the casting, a secure 2-pin strand line (17) (see device overview
on page 8) led to a board, on which a magnet contact (reed contact) is
found. It is soldered under casting and on the conductor board with the
magnet contact.

Secure keyboard connection

From the casting, a secure 14-pin flat band line with connector is guided
through (7) (see device overview on page
This connector should be placed on the 14 pin pin in the casing cover
before the device is screwed down.