1 General
The FernTel IP Z2 UL telephone is an explosion proof UL certified version of the
weatherproof
FernTel IP / IP150
telephone with all its features. The operating
manual is still valid, with the addition of the following items.
1.1 Operation
The FernTel IP Z2 UL telephone is used as a stationary device in areas potentially
endangered by an explosive gas atmosphere.
1.2 Description
The telephone FernTel IP Z2 UL is allowed to be operated within Class I, Division 2,
Groups A, B, C and D or non-hazardous locations only.
The telephone is realized according to the following:
• Working environment temperature range:
o
-20°C ≤ Ta ≤ +55°C (-4°F ≤ Ta ≤ +131°F)
• Storage and transport temperature:
o
-25°C ≤ Ta ≤ +70°C (-13°F ≤ Ta ≤ +158°F)
2 Commissioning
For operation and commissioning, the application of standard IEEE 802.3af is
compulsory.
The FernTel IP Z2 UL telephone must be connected to a LAN (Local Area Network)
connection equipped with PoE (Power over Ethernet).
Contrary to the standard FernTel IP / IP150, the FernTel IP Z2 UL has no LAN cable
plug bush. Also, there is no second LAN receptacle on the right-hand side of the
telephone. Thus the LAN plug for the LAN cable is no longer part of the delivery.
Instead of that a plug socket for cable mounting will be delivered.
2.1 Connecting
Connect the device using a RJ45 plug (socket) with the following normative PoE
allocation: