Clean inside of body and stem housing. Light

5.

grease, compatible with line fluid, can be used on

ball, seals and stem surface.

Note: A spare parts list is available for this valve.
Please refer to explosion view below for identifica-
tion. Please specify specific valve number to ensure
proper parts are ordered. Marwin Valve does not
take responsibility for incorrectly ordered spare
parts.

Re-Assembly

A. Stem

Replace thrust washer (8) then insert the stem from

1.

inside the body.

Install stem packing (7), gland nut (6) and tighten

2.

until snug, then one-half turn. To avoid rotation of

stem, insert the handle and ball.

Install handle (2) and handle nut (3) then tighten.

3.

B. Ball, Seats and Seals

Place the stem in closed position and insert the

1.

ball, aligning groove in ball with bottom of stem.

Position the ball in the open position then insert the

2.

seats and body seals.

Thread in end cap.

3.

Spare Parts Kit

Item #

Quantity

Part Name

7

1

Stem Packing

8

1

Thrust Washer

9

2

Seat

12

1

Body Seal

Testing

After completing the reassembly, check that valve

1.

operates smoothly by opening and closing valve

several times.

If entire valve was removed from line and if facili-

2.

ties are available, test the ball valve to appropriate

specifications.

Troubleshooting

A. Stem Leakage

Leakage in the stem packing area may be elimi-

1.

nated by increasing the torque on the gland nut (6)

in one-quarter turn increments. If leakage persists,

replace stem packing (7).

B. Body Seal Leakage

Check the torque of the end cap. Replace body

1.

seal (12) if leakage persists.

C. In-Line or Seat Leakage

Check to be sure valve is in fully closed position. If

1.

leakage persists, the valve must be disassembled

and damaged parts replaced.