5.6. INSTALLATION OF TEMPERATURE PROBE
The temperature probe must be connected to the control unit and to
the duct (1) of a kit (see diagram below) and has a length of 2.5 m.
Greater distances require the use of and extension to be provided by
the installer.
PROBE INSTALLATION
Insert the plastic piece C in D and screw in B without forcing it.
On the threaded part of piece D insert washer E
The group thus formed A1 must be inserted on the rigid part of
the cable of probe A
Identify the pass-through hole for insertion of the probe on the
duct (1); on the grille at lower right alongside the fan.
Insert in the hole the cable of probe A with the block A1 and
secure it on the other side with the nut F
Insert the other end of the cable of probe A in the control unit
in the indicated position (12-11)
A1
F
B
A1
A
B
C
D
E
F