8 - ELECTRICAL CONNECTION

OPERATING MODE

The operating mode for hydro stoves is only AUTOMATIC (there is no manual operating mode available). The modulation of the flame is

controlled according to the "System configuration" by the room temperature probe located at the back of the appliance (see img.), by the

external thermostat, by the temperature of the water in the boiler, or by the NTC probes.

ELECTRICAL CONNECTIONS

TERMINAL BLOCK CONTACTS
POS.1-2 EXTERNAL THERMOSTAT/PUFFER THERMOSTAT

POS.8 NEUTRAL THREE-WAY VALVE

POS.3-4 PUFFER/BOILER PROBE

POS.9 THREE-WAY VALVE PHASE (heating)

POS.5 EARTHING
POS.6-7 AUXILIARY STOVE