Hotpoint Ariston CG65SG1 (W) IT/HA H User Manual
Page 20

20
GB
Table of burner and nozzle specifications
CG65SG1 IT/HA H
S R
TC A
Table 1
Liquid Gas
Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm) (mm) *** **
(mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218
214
116 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138
136
106
181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73
71 79 95
Tripple Ring
(TC)
130 3.25 1,5
63 2x65 236 232 2x99 309
Oven -
2.60
1.0
52
78
189
186
119
248
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C 1013 mbar-dry gas
***
Butane P.C.S. = 49,47 MJ/Kg
** Propane P.C.S. = 50,37 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³
TECHNICAL DATA
Oven Dimensions
HxWxD
31x43,5x43,5 cm
Volume
58 l
Useful
measurements
relating to the
oven compartment
width 46 cm
depth 42 cm
height 8,5 cm
Voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate.
EC Directives 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
04/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
90/68/EEC dated 22/07/93 and
subsequent amendments. -
2002/96/EC.
1275/2008(Stand-by/Off-mode)