Wiring diagram, Installation, Start-up – Elkay ERW20-1C User Manual

Page 2: Trouble shooting & maintenance

background image

97644C (Rev. B - 2/04)

ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484

REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

ERW20-1C

ITEM

NO.

PART NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17*

18

19

20

21

22

23

24

25

26

27

28

29

30

31

50196C

28180C

23101C

23104C

28178C

28179C

23089C

28175C

27957C

28176C

30235C

30768C

30812C

35882C

35895C

35921C

36074C

30233C

30234C

66632C

66625C

70772C

66204C

66629C

36079C

35845C

35846C

30560C

70482C

70483C

70274C

ITEMIZED PARTS LIST

DESCRIPTION

*INCLUDES RELAY & OVERLOAD. IF UNDER

WARRANTY, REPLACE WITH SAME COMPRESSOR

USED IN ORIGINAL ASSEMBLY.

NOTE: All correspondence pertaining to any of the

above water cooler or orders for repair parts MUST

include model number and serial number of cooler, name

and part number of replacement part.

Grommet

Panel Insulation Box (Rear)

Panel End

Box Insulation (Front)

Terminal Box

Grille

Cover Terminal Box

Rear Panel

Cover Insulation Box

Base Ass'y

Terminal Cover

Solenoid Valve

Overload

Cold Control

Cold Control Freeze Protect

Capacitor

Compressor Service Pak

Overload Spring

Clip Compressor

Condenser

Evaporator

Drain Plug

Drier

Heat Exchanger

Relay

Cap-Capacitor End

Bracket-Capacitor

Terminal Cover

Male Connector Fitting

Elbow Fitting

Compressor Mounting Sleeve

WIRING DIAGRAM

INSTALLATION

1. Potable water inlet and outlet are 3/8" (9 mm) O.D. tube located on

top of unit. Water cooled condenser inlet and outlet are 3/8" (9 mm)

O.D. tube located on right front of unit. Installer to provide air gap at

condenser water outlet to comply with local plumbing specifications.

Contractor to supply connections as required.

2. Connecting lines to be of copper, thoroughly flushed to remove all

foreign matter before being connected to cooler. If flushing does

not remove all particles, a water strainer should be installed in supply

line.

3. Connect cooler to building supply line with a shut-off valve and install

a union connection between the valve and cooler.

4. Electrical: Make sure power supply is identical in voltage, cycle, and

phase to that specified on cooler serial plate. Never wire compressor

directly to the power supply

START-UP

1. Open supply line valve.

2. Purge air from all water lines by operating bubbler valve of fountain.

3. Connect to electrical power.

TROUBLE SHOOTING & MAINTENANCE

Temperature Control: Factory set for 50° F water under normal

conditions. To adjust water temperature, turn screw on Item No. 14

clockwise for colder, counter clockwise for warmer.

Ventilation: Cabinet louvers should be periodically cleaned with brush,

air hose or vacuum cleaner. Excess dirt or poor ventilation can cause

no cold water and compressor cycling on the compressor overload

protector

Lubrication: Motors are lifetime lubricated.