beautypg.com

Maintenance and service – Enviro Sienna Indoor Gas Fireplace User Manual

Page 12

background image

12

Maintenance And Service

c) Check that the screw is clean and if necessary

remove dirt.

d) Flip the screw (refer to Figure 13).
e) Using the Allen wrench as shown in Figure 12,

rotate the screw clockwise until a torque of 9 inch

lbs. WARNING! Do not over tighten the screw.

It is recommended that you grip the wrench by

the short side.

f) Verify that if the conversion is from NG to LPG,

the screw must be re-assembled with the red o-

ring visible (refer to Figure 14). If the conversion

is from LPG to NG, the red o-ring of the screw

must be not visible.

g) Re-attach the black protection cap that was

removed in step a (Figure 11).

Figure 13: Flip valve

screw.

8. Reinstall the burner, brick panels,

log set, embers, and glass door. Also

refer to S

ECONDARY

I

NSTALLATION

-

I

NSTALLING

L

OG

S

ET

AND

E

MBERS

. When

re-installing the burner, ensure that

the burner to pilot hood relationship

is similar to what is shown in Figure

15. On some units you will need to

pay special attention when installing

Figure 14: O-ring on valve screw.

the burner that the venturi adjustment rod is properly installed into

the venturi adjustment piece welded to the burner venturi tube

9. Reconnect the main gas line if it was disconnected and open the

shut-off valve at the gas line to the unit.

10. Use a small brush to apply a warm soapy water solution to all gas

connections (use a half dish soap and half warm water). If a gas leak

is present, bubbling will occur. Gas leaks can be repaired by using an

approved pipe thread sealant or approved Teflon tape. NEVER USE

AN OPEN FLAME WHEN TESTING FOR LEAKS.

11. Reconnect the electrical power to the unit.

Figure 12: Removing valve

screw.

b) Insert a

5

/

32

” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 12), rotate

it counter-clockwise until it is free and extract it.

12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and

operation and proper flame appearance. Also refer to S

ECONDARY

I

NSTALLATION

- L

OG

S

ET

AND

E

MBERS

I

NSTALLATION

for a flame appearance picture.

13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the

unit has been converted to a different fuel type.

Figure 15: Burner to pilot hood

relationship.