beautypg.com

Operation of quick connect fittings wiring diagram – Elkay HRC32W User Manual

Page 2

background image

97582C (01/21/2000)

HRC32W

DESCRIPTION

23152C
28070C
27698C
28032C
23158C
23159C
26701C

34783005

35882C
66218C

31723000

30440C
30768C

43242004
48000036

30248C

48000070
48000067
48000069
48000068
19037000

100806740570

66216C
70772C

31738002

70020C

1
2
3
4
5
6
7
8
9

10

11

12
13
14

*15

16
17
18
19
20
21
22
23
24
25
26

PART NO.

BOX - INSULATION
BASE ASSY
PANEL
PANEL - FRONT/REAR
COVER - INSULATION BOX
BRACKET - CONDUIT
CABINET
WASHER - LOCK
CONTROL - COLD
CONDENSER ASSY
STRAINER
CAPACITOR
SOLENOID VALVE
CAPILLARY TUBE
COMPRESSOR
OVERLOAD
GASKET - TERM COVER
OVERLOAD SPRING
BALE STRAP
COVER - TERMINAL
CLIP - COMPRESSOR MTG
GROMMET - COMPRESSOR MTG
EVAPORATOR ASSY
EVAPORATOR DRAIN PLUG
DRIER
NUT

ITEM NO.

PARTS LIST

*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE

WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.

NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE ABOVE

WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE

MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF

REPLACEMENT PART.

NOTE: FOR USE WITH PHOTO PROCESSING APPLICATIONS,

ADJUST THERMOSTAT TO WARMER SETTINGS.

The grounding of electrical equipment such as telephone, computers, etc., to water

lines is a common procedure. This grounding may be in the building, or may occur

away from the building. This grounding can cause electrical feedback into a water

chiller, creating an electrolysis which causes a metallic taste or an increase in the

metal content of the water. This condition is avoidable by using the proper materials

indicated below. Drain fittings which are provided by the installer should be plastic to

electrically isolate the chiller from the building plumbing system.

Temperature Control: Factory set for 50°F water (± 5°) under normal conditions. For

colder water, adjust screw on item no. 9 clockwise.

Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a

brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no

cold water and compressor cycling on the overload protector.

Lubrication: Motors are lifetime lubricated.

Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free plug

which utilizes an o-ring seal. To remove plug from cooler, relieve water pressure,

pull the collar towards the fitting and pull the fitting off the tube. To install plug,

push fitting straight onto tubing until it reaches a positive stop, approximately 3/4”.

IMPORTANT! INSTALLER PLEASE NOTE:

TROUBLE SHOOTING & MAINTENANCE

START-UP

1. Open supply line valve.

2. Purge all air from all water lines by operating bubbler valve of fountain to which

cooler is connected. A steady stream flow assures that all air is removed.

3. Rotate fan blade to assure proper clearance and free action.

4. Connect to proper electrical power.

TUBE IS SECURED

IN POSITION

SIMPLY PUSH IN

TUBE TO ATTACH

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

WIRING DIAGRAM

5

9

12

3

4

13

7

14
23

25

1

24

2 8, 26

6

15,16,17

18,19,20

21, 22 14 11

10