beautypg.com

C361/c371 operating mechanisms, C361 variable depth disconnects, C361/c371 operating mechanisms - 29 – Eaton Electrical Disconnect Switches User Manual

Page 25: Product description, Options and accessories

background image

24

For more information visit us at: www.eatonelectrical.ca

December 2004

Operating Mechanisms with Disconnect Switches

– Variable Depth

Complete Operating

Handle Only —

Mechanism — C361NE1

C361H1

Product Description

Type C361 Disconnect Switches are
suitable for installation in control
enclosures having a right-hand flange.
Fusible disconnect switches will accept
R fuses as standard. Field installable
rejection kits are supplied as standard
on 100A and 200A clips. For 30A and
60A rejection clips, see footnote

.

The switch is CSA/UL component rec-
ognized for use on systems with up to
200,000 rms symmetrical amperes
available fault current when Class R
clips are supplied. A standard connect-
ing rod is supplied with switch.

Options and Accessories

Table 1. Electrical Interlocks

Table 2. Connecting Rods — Increase
Maximum Allowable Depth by 5 Inches

Table 3. Operating Mechanism Variable Depth with Disconnect Switch — Right-Hand Mounting

Dimension shown is from panel to flange surface.

Refers to rating of switch only.

Components individually boxed and shipped in overpack carton.

For rejection clips, add Suffix Letter R to listed Catalogue Number, and add $9. to price. Example: C361SC121R.

Table 4. Handle Only

Circuit

Catalogue
Number

1NO-1NC
2NO-2NC

DS200EK1
DS200EK2

Application

Catalogue
Number

Disconnect Switches

30, 60, 100 and 200A

Circuit Breakers

150, 250 and 400A

C371CS1

Circuit Breakers

600, 800 and 1200A

C371CS2

Disconnect
Switch Size
(Amperes)

Variable
Depth
Mounting
Range
Minimum/
Maximum
(Inches)

Maximum Horsepower Ratings

Fuse Clip Rating
(Amperes) Non-
interchangeable
Type for Class
H, J, K or R Type
Fuses Only

Switch and
Operating
Mechanism Only
DOES NOT
Include Handle

Switch and Operating Mechanism
with 4-Inch Handle

AC System Volts
(Motor Volts)

DC Using
2 Poles
250V
Maximum

For NEMA 1 or 12
Enclosure

For NEMA 4
Enclosure

208
(200)

240
(230)

480
(460)

600
(575)

250V

600V

Catalogue
Number

Catalogue
Number

Catalogue
Number

30

7 to 16

7-1/2

7-1/2

15

20

5

Non-fusible

C361NC

C361NC1

C361NC2

30
60

30

C361SC21
C361SC61

C361SC121

C361SC161

C361SC221

C361SC261

60

7 to 16

15

15

30

50

10

Non-fusible

C361ND

C361ND1

C361ND2

60

30
60

C361SD22
C361SD62

C361SD122

C361SD162

C361SD222

C361SD262

100

7 to 16

25

30

60

75

20

Non-fusible

C361NE

C361NE1

C361NE2

100

100

C361SE263

C361SE1263

C361SE2263

200

7 to 16

40

60

125

150

40

Non-fusible

C361NF

C361NF1

C361NF2

200

200

C361SF264

C361SF1264

C361SF2264

Application

Operating Handle
Length in Inches
(mm)

NEMA Type
Enclosure

Catalogue
Number

For use with 30, 60,
100 and 200 Ampere
Disconnect Switches

4.00 (101.6)
4.00 (101.6)
6.00 (152.4)
6.00 (152.4)

1-12
4
1-12
4

C361H1
C361H2
C361H3
C361H4