3
Replacing a Boot HBA
3-33
Configuring an EMC Boot Device
Replacing a Boot HBA
If a boot HBA fails, you can replace it with a new one as described in
this section.
EMC Symmetrix
Follow the procedure under Configuring a Symmetrix Boot Device.
EMC CLARiiON
◆
Shut down and power off the server.
◆
Replace the HBA in the identical location and reconnect cabling.
◆
(Fabric configuration only) Repeat the procedure under Preparing
the Fabric on page 3-15, and replace the old HBA’s WWPN with
the new HBA’s WWPN.
◆
Repeat the procedure under Verifying HBA Driver and Digital
Signature Installation on page 3-25.