beautypg.com

Initial installation, Preparation for installation, Clearances to combustibles – Enviro ASCOT VENTED GAS FIREPLACE HEATER User Manual

Page 12

background image

Initial Installation

QUALIFIED INSTALLERS ONLY

WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can

result in carbon monoxide (CO) poisoning and possible death.

P

REPARATION

F

OR

I

NSTALLATION

:

• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is

found, please report it to both the carrier and your dealer as soon as possible.

• Before beginning, carefully check the glass door and the log set
• Locate a position where the flue system of the stove can be properly installed without damaging the

integrity of the building; e.g. cutting a wall or ceiling joist.

• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat

circulation and comfort.

• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8

m) of the stove.

• The flow of combustion and ventilation air must not be obstructed.

C

LEARANCES

TO

C

OMBUSTIBLES

:

A) Sidewall to unit

10 inches (254 mm)

B) Backwall to unit

21⁄2 inches (64 mm)

C) Corner to unit

21⁄2 inches (64 mm)

D) Ceiling bottom of unit 60 inches (1524 mm)
E) Floor

0 inches

(0 mm)

Note: Must have hearth pad if installed on a

carpeted surface.
If this unit is installed in an alcove the alcove must meet

these minimum dimensions:
Width

48 inches (1219 mm)

Height

60 inches (1524 mm)

Maximum Depth

24 inches (610 mm)

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

�����

���� ����

��

��

��

��

�������� ����

��

��

��

Figure 12: Clearances to combustibles.

12