Product specification – Empire Comfort Systems VFSR-24-3 User Manual
Page 7

26333-3-1210
Page 7
PrODucT SPecIFIcATION
PrODucT SPecIFIcATION
Natural Gas
Propane Gas
Variable
Millivolt
Manual
Variable
Millivolt
Manual
Regulator pressure setting
3.5" W.C.
3.5" W.C.
6.0" W.C.
10.0" W.C.
10.0" W.C.
10.0" W.C.
Gas inlet pressure
Max.
10.5" W.C.
10.5" W.C.
10.5" W.C.
13.0" W.C.
13.0" W.C.
13.0" W.C.
Min.
5.0" W.C.
5.0" W.C.
7.0" W.C.
11.0" W.C.
11.0" W.C.
11.0" W.C.
Model
Gas
Valve Type
BTUH Max. Rate
BTUH Med. Rate
BTUH Min. Rate
VFSV-16
Natural
Variable
25,000
—
17,500
VFSV-16
Propane
Variable
22,500
—
15,750
VFSR-16
Natural
Millivolt
25,000
—
17,500
VFSR-16
Propane
Millivolt
22,500
—
15,750
VFSV-18
Natural
Variable
32,000
—
19,000
VFSV-18
Propane
Variable
32,000
—
19,000
VFSR-18
Natural
Millivolt
32,000
—
22,000
VFSR-18
Propane
Millivolt
32,000
—
22,000
VFSM-18
Natural
Manual
32,000
27,000
22,000
VFSM-18
Propane
Manual
32,000
27,000
22,000
VFSV-24
Natural
Variable
36,000
—
20,000
VFSV-24
Propane
Variable
36,000
—
20,000
VFSR-24
Natural
Millivolt
36,000
—
25,000
VFSR-24
Propane
Millivolt
36,000
—
25,000
VFSM-24
Natural
Manual
36,000
27,000
22,000
VFSM-24
Propane
Manual
36,000
27,000
22,000
VFSV-30
Natural
Variable
38,000
—
20,000
VFSV-30
Propane
Variable
38,000
—
20,000
VFSR-30
Natural
Millivolt
38,000
—
26,000
VFSR-30
Propane
Millivolt
38,000
—
26,000
VFSM-30
Natural
Manual
38,000
27,000
22,000
VFSM-30
Propane
Manual
38,000
27,000
22,000