Combustible material fireplace preparation – Empire Comfort Systems VFSR-24-3 User Manual
Page 11
26333-3-1210
Page 11
FOr MASONry BuILT FIrePLAceS
Free OPeNING AreA OF cHIMNey DAMPer FOr VeNTING
cOMBuSTION PrODucTS FrOM DecOrATIVe APPLIANceS
FOr INSTALLATION IN SOLID FueL BurNING FIrePLAceS
•
Turn off gas supply to fireplace or firebox.
•
Have the fireplace floor and chimney professionally cleaned to
remove ashes, soot, creosote or other obstructions. Have this
cleaning performed annually after installation.
•
Seal any fresh air vents or ash clean-out doors located on floor
or wall of fireplace. If not, drafting may cause pilot outage or
sooting. Use a heat-resistant sealant. Do not seal chimney flue
damper.
Install and operate the appliance as directed in this manual.
FOr FAcTOry BuILT FIrePLAceS
Free OPeNING AreA OF cHIMNey DAMPer FOr VeNTING
cOMBuSTION PrODucTS FrOM DecOrATIVe APPLIANceS
FOr INSTALLATION IN SOLID FueL BurNING FIrePLAceS
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
Figure 7
No greeting card, stockings or ornamentation of any type should be
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Figure 8
cOMBuSTIBLe MATerIAL
FIrePLAce PrePArATION
Appliance Input rate (BTu/hr)
20
30
40
chimney
Height* (ft)
Minimum Opening** (sq. in.)
10
11.3
16.6
22.1
15
8.6
12.6
17.3
20
7.5
10.8
14.5
25
6.6
9.6
12.6
30
6.2
9.1
11.3
35
5.7
8.0
10.8
40
5.3
7.5
10.2
* Height is from hearth to top of chimney and the minimum height
is 10 feet.
** Chart shows minimum opening (sq. in.) for given height and
input rate.
Appliance Input rate (BTu/hr)
20
30
40
chimney
Height* (ft)
Minimum Opening** (sq. in.)
6
17.6
25.7
33.8
8
16.5
23.7
31.2
10
15.1
21.7
28.7
15
14.1
19.9
26.1
20
12.9
18.5
23.7
30
12.2
16.9
21.6
* Height is from hearth to top of chimney and the minimum height
is 6 feet.
** Chart shows minimum opening (sq. in.) for given height and
input rate.