Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card

supplied with unvented room heater.

3. Installer should show owner how to start and operate unvented

room heater.

Always consult your local Building Department regarding

regulations, codes or ordinances which apply to the installation

of an unvented room heater.
This appliance may be installed in an aftermarket* manufactured

(mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from

the manufacturer.

This appliance is only for use with the type of gas indicated on

the rating plate. This appliance is not convertible for use with

other gases.

WARNING: ANY CHANGE TO THIS HEATER OR ITS

CONTROLS CAN BE DANGEROUS.

Improper installation or use of the heater can cause serious

injury or death from fire, burns, explosion or carbon

monoxide poisoning.

This series is design certified in accordance with American

National Standard Z21.11.2 by the Canadian Standards Association

Laboratories as an Unvented Room Heater and should be installed

according to these instructions.
Any alteration of the original design, installed other than

as shown in these instructions or use with a type of gas not

shown on the rating plate is the responsibility of the person

and company making the change.
VFP(32,36)FP(30,31)L Only

750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts

(electrical current) which energizes the magnet in the gas valve.

After 30 seconds to 1 minute time period you can release the gas

control knob and the pilot will stay ON. Allow your pilot flame to

operate an additional one (1) to two (2) minutes before you turn the

gas control knob from the PILOT position to the ON position. This

time period allows the millivolts (electrical energy) to build-up to

a sufficient level allowing the gas control to operate properly.
Important

All correspondence should refer to complete Model Number,

Serial Number and type of gas.
Attention: During initial use of ceramic log you will detect

an odor as the ceramic log is cured. Also, during the curing

process the ceramic log will burn with a yellow flame.
Notice:
During initial firing of this unit, its paint will bake out,

and smoke will occur. To prevent triggering of smoke alarms,

ventilate the room in which the unit is installed.
Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other

combustible material other than wood flooring the appliance shall

be installed on a metal or wood panel extending the full width and

depth of the appliance.
The base referred to above does not mean the fire-proof base as

used on wood stoves. The protection is for rugs that are extremely

thick and light colored tile.

Solid-fuels shall not be burned in a masonry or UL 127 factory-

built fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment

or accessories and repair and servicing of equipment shall be

performed only by a qualified agency. The term "qualified

agency" means any individual, firm, corporation or company

which either in person or through a representative is engaged in

and is responsible for (a) the installation or replacement of gas

piping or (b) the connection, installation, repair or servicing of

equipment, who is experienced in such work, familiar with all

precautions required and has complied with all the requirements

of the authority having jurisdiction.

State of Massachusetts: The installation must be made by

a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental

room heaters shall provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.

The installation must conform with local codes or, in the absence of

local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 1430 Broadway,

New York, N.Y. 10018.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be

reduced at the rate of 4 percent for each 1,000 feet (305m) above

sea level. Contact the manufacturer or your gas company before

changing spud/orifice size.
Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the

Btu output of the unit. Contact the gas company for the heating

value. Contact the manufacturer or your gas company before

changing spud/orifice size.

WARNING: This appliance is equipped for (natural gas or

propane) gas. Field conversion is not permitted.