beautypg.com

Fireplace framing and installation – Empire Comfort Systems VFP32FP User Manual

Page 14

background image

Page 14

20101-0-0306

1. Place fireplace in framing opening.

2. Using the four (4) nailing flanges provided with the fireplace,

attach two (2) flanges on each side. Attach flanges through

prepunched holes. Additional hole locations will be used for

different finishing material with thicknesses of 1/2”, 5/8” and

3/4”. Attach these flanges with screws provided, two (2) per

nailing flange.

3. Nailing flanges should fit directly against framing material.

Use at least one (1) nail per tab to secure in place.

Attention: Add 3 3/4" to "A" Dimensions when using flush

mantel base.

Figure 12

Fireplace framing can be built before or after the fireplace is set

in place. Framing should be positioned to accommodate wall

covering and fireplace facing material. The fireplace framing

should be constructed of 2 x 4 lumber or heavier.

Figure 11

Figure 10

VFP32FP

VFP36FP

"A"

36 1/4"

38 1/4"

"B"

34 1/2"

39 1/2"

"C"

17 7/8"

17 7/8"

NAIL OR OTHER SUITABLE FASTENER

FIREPLACE FRAMING AND INSTALLATION