Installing the hood

For the most eficient air flow exhaust, use a

straight run or as few elbows as possible.

Vent unit to outside of building and recirculating.

On avarage 2 to 3 hours are necessary to com-

plete installation (without considering cut to be

done on wall and or on cabinet, installation of

ducts , conduit and electrical connections to the

mains).

The hood is fitted with Screws and Drywall

Anchors suitable for most surfaces, consult a

Qualified Installer, check if they perfectly fit with

your cabinet/wall.

Do not use flex ducting.

COLD WEATHER installations should have an

additional backdraft damper that is already in

stalled backward cold air flow and a nonmetallic

thermal to minimize break to minimize conduction

of outside temperatures as part of the ductwork.

The damper should be on the cold air side of the

thermal break.

The break should be as close as possible to

where the ducting enters the heated portion of

the house.

Make up air: Local building codes may require

the use of Make-Up Air Systems when using

Ducted Ventilation Systems greater than specified

CFM of air movement.

The specified CFM varies from locale to locale.

Consult your HVAC professional for specific

requirements in your area.

Installing the hood

Typical installation

Min installation height from the range top to the

bottom of the hood is 30” if a gas range is used

or 24” to 30” if an electric range is used.

These hoods are not recommended to be used

over indoor grills.

The hood may be installed vented to the outdoors, or
it can be installed for recirculating operation

(recirculating accessories not supplied with the

hood).

This hood can be installed over any electric and

gas cooktop/range.

This hood must not be installed over any

professional cooktop / range.