be installed and connected in accordance
with the current installation regulations.
Particular attention shall be given to the rel-
evant requirements regarding ventilation.
The room containing the appliance should
have an air supply in accordance with BS.
5440: Part 2 Current Edition.
All rooms require an openable window or
equivalent and some rooms will require a
permanent vent as well.
For room volumes up to 5m

3

an air vent of

100cm

2

is required: for room volumes be-

tween 5m

3

and 10m

3

an air vent of 50cm

2

is

required.
If the room has a door that opens directly to
the outside, no air vent is required.
For room volumes that exceed 11m

3

no air

vent is required.
If there are other fuel burning appliances in
the same room, BS.5440: Part 2 Current Ed-
ition should be consulted to determine the
requisite air vent requirements.
Prolonged intensive use of the appliance may
call for additional ventilation, for example
opening a window, or more effective ventila-
tion, for example increasing the level of me-
chanical ventilation where present.

Moving the appliance
You may damage some soft or badly fitted
floor coverings when you move the appli-
ance.
The floor covering under the appliance
should be securely fixed so it does not ruck
up when you move the appliance across it.
Alternatively you could remove the floor cov-
ering.
This appliance is heavy and care must be
taken when moving it.
Do not try to move the appliance by pulling
the door handles.
To move the appliance open the grill door.
Raise the appliance off its front feet by lifting
it from inside the oven. Pull the appliance for-
ward.
When you replace the appliance push it back
to the stop and make sure there is the same
gap at each rear corner.

For your safety
Do not try to disconnect the appliance from
the gas supply if the supply pipe does not
have a bayonet connection, as described in
the installation instructions. If this is the case

contact the person who installed the appli-
ance.

Location of the appliance
This appliance must not be installed in a bed-
sitting room of volume less than 20m

3

or in a

bathroom, shower room or garage.
It is essential that the appliance is positioned
as Fig 1. a.
Shelves, wall cabinets and cooker hoods
must be fitted a minimum of 750mm directly
above the top of the hotplate (or greater for
cooker hoods if recommended by manufac-
turers instructions) and 400mm above the
hotplate when fitted in line with the outside of
the appliance.
If the units are intended to be fitted adjacent
to the appliance but less than 400mm above
the hotplate, then a minimum space of
50mm must be maintained between the
sides of the unit and the appliance as Fig 1.b.
Curtains must not be fitted immediately be-
hind the appliance or within 150mm of the
sides of the hotplate.
If fitted next to or between two base units a
minimum space of 2mm must be left be-
tween each unit and the sides of the appli-
ance.
The levelling feet fitted to the appliance will
achieve a nominal height to hotplate of
907mm + / - 5mm.

Fig 1.a

Fig 1.b

L.P.G. cookers MUST NOT be installed
below ground level i.e. in a basement or
aboard any boat, yacht or other vessel.

Levelling the appliance
Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance.