Electrolux EI36EC45KS User Manual
Electric cooktop installation instructions
1
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
3 1/8
(7,9)
5 5/8
(14,3)
3 ½
(8,9)
7 ½
(19,1)
6 5/8
(16,8)
A
I
B
C
G
H
30” Min. *
(76.2 cm)
E
F
D
All dimensions are in inches (cm).
P/N 318205426 (1202) Rev. B
English – pages 1-6
Español – pages 7-12
Français - pages 13-18
Notes - pages 19-20
Cooktop Dimensions
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or
four-wire cable, 240/208 volt, 60 hertz, AC only electrical
supply with ground.
• Minimum distance between cooktop and overhead cabinetry
is 30” (76.2 cm).
* 30” (76.2 cm) min. for unprotected cabinet
24” (61 cm) min. for protected surface
Cooktop Cutout
Dimensions
Figure 1
Printed in Canada
4” X 8” (10.2 cm x 20.3 cm)
opening to route armored cable
if a panel is present
Front
Rear
Side view
Countertop
Countertop
INSTALLATION AND SERVICE MUST BE PERFORMED
BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
Canada
United States
PRODUCT DIMENSIONS
MODEL
A. WIDTH
B. DEPTH
C. HEIGHT
D. HEIGHT
E. BOX WIDTH
F. BOX DEPTH
30’’ Ceramic Model
30¾ (78.1)
21¾ (55.2)
3 1/8 (7.9) 6 5/8 (16.8)
28 5/8 (72.7)
19¼ (48.9)
36’’ Ceramic Model
36¾ (93.3)
21¾ (55.2)
3 1/8 (7.9) 6 5/8 (16.8)
34 5/8 (87.9)
19¼ (48.9)
CUT OUT DIMENSIONS
MODEL
G. WIDTH
H. DEPTH
I. HEIGHT BELOW
COOKTOP
MINIMUM
MAXIMUM
MINIMUM
MAXIMUM
30’’ Ceramic Model
29¾ (75.6)
30 (76.2)
20 3/8 (51.8)
20 5/8 (52.4)
8½ (21.6)
36’’ Ceramic Model
35¾ (90.8)
36 (91.4)
20 3/8 (51.8)
20 5/8 (52.4)
8½ (21.6)