Commissioning

When the hob has been fully installed it will be

necessary to check the minimum flame setting.

To do this, follow the procedure below.

- Turn the gas tap to the MAX position and ignite.

- Set the gas tap to the MIN flame position then

turn the control knob from MIN to MAX several

times. If the flame is unstable or is extinguished

follow the procedure below.

Procedure:

Re-ignite the burner and set to MIN.

Remove the control knob.

The adjustment screw is located down

the centre of the gas tap control shaft or

on the lower right hand side of the shaft

(see diagram).

To adjust, use a thin bladed screwdriver

and turn the adjustment screw until the

flame is steady and does not extinguish,

when the knob is turned from MIN to

MAX. Repeat this procedure for all

burners.

Pressure Testing

Remove pan support and front left

burner cap and crown.

Fit manometer tube over the injector.

Turn on the burner gas supply and ignite

another burner supply.

The pressure reading should be

nominally 20mbar and must be between

17 mbar and 25mbar.

Turn off the burner supplies.

a) Minimum adjustment screw

b) Tap

FO
1032

F

F

a